Error analysis and research of rail straightness detector based on laser displacement sensor

The detection of the rail straightness is crucial to the maintenance of the track. This paper designed a rail straightness detector based on laser displacement sensor. Based on the theoretical analysis of the detection error of the detector, the error analysis platform of the detector is built based on the working face of the precision marble measuring block. The mobilized medium moving average filtering algorithm and the linear fitting calibration method are treated with the random error and systemic error of the detector data collection system; The vibration error was tested and analyzed, and the laws of various errors were obtained. The minimum daily method was used to fit the system variable error, which provided error compensation measures for the detector.

Authors

Institutions

Publication Details

Published
2024-08-05
DOI
https://doi.org/10.1117/12.3039221
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Error analysis and research of rail straightness detector based on laser displacement sensor

Lijie wang, Weichao Shi, Zheyi wang, Dekai Xu
Advanced Measurement and Metrology Techniques
article

Error analysis and research of rail straightness detector based on laser displacement sensor

Lijie wang, Weichao Shi, Zheyi wang, Dekai Xu
article en

Abstract

The detection of the rail straightness is crucial to the maintenance of the track. This paper designed a rail straightness detector based on laser displacement sensor. Based on the theoretical analysis of the detection error of the detector, the error analysis platform of the detector is built based on the working face of the precision marble measuring block. The mobilized medium moving average filtering algorithm and the linear fitting calibration method are treated with the random error and systemic error of the detector data collection system; The vibration error was tested and analyzed, and the laws of various errors were obtained. The minimum daily method was used to fit the system variable error, which provided error compensation measures for the detector.

Xi'an University of Technology (CN)
Openalex Percentile: Top 88%
Advanced Measurement and Metrology Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.