Gaussian reconstruction algorithm for under-sampling atomic force microscopy images based on cassini elliptical scanning

Non-grid scanning of atomic force microscope can improve the imaging speed compared with traditional grid scanning, but when the speed is increased, the imaging quality may decrease. In this paper, the AFM system is built by ourselves, and the standard grid and human vascular smooth muscle cells are imaged by Cassini ellipse under-sampling. The samples of Cassini under-sampling are reconstructed by Gaussian regression, and compared with the traditional cubic spline interpolation reconstruction method. The results show that Gaussian regression has obvious improvement over traditional interpolation reconstruction for standard samples. When scanning cells, keep the under-sampling rate greater than 45%, so as to ensure a better reconstruction result.

Authors

Institutions

Publication Details

Published
2024-08-05
DOI
https://doi.org/10.1117/12.3039181
Citations
1
Primary Topic
Force Microscopy Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.34
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gaussian reconstruction algorithm for under-sampling atomic force microscopy images based on cassini elliptical scanning

Jiarui Gao, yu Liao, benliang Zhu, Xiangnan Zhang et al.
1 citations
Force Microscopy Techniques and Applications
0.34
article

Gaussian reconstruction algorithm for under-sampling atomic force microscopy images based on cassini elliptical scanning

Jiarui Gao, yu Liao, benliang Zhu, Xiangnan Zhang, jianhao lai, haoyan Zang
article en
1 citations

Abstract

Non-grid scanning of atomic force microscope can improve the imaging speed compared with traditional grid scanning, but when the speed is increased, the imaging quality may decrease. In this paper, the AFM system is built by ourselves, and the standard grid and human vascular smooth muscle cells are imaged by Cassini ellipse under-sampling. The samples of Cassini under-sampling are reconstructed by Gaussian regression, and compared with the traditional cubic spline interpolation reconstruction method. The results show that Gaussian regression has obvious improvement over traditional interpolation reconstruction for standard samples. When scanning cells, keep the under-sampling rate greater than 45%, so as to ensure a better reconstruction result.

South China University of Technology (CN)
Openalex Percentile: Top 42%
Force Microscopy Techniques and Applications
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Gaussian reconstruction algorithm for under-sampling atomic force microscopy images based on cassini elliptical scanning — Jiarui Gao, yu Liao, et al. · (2024) | TGRS Research Map | TGRS