Design of special pipeline helix angle measurement system based on orifice suspended guide rail

Due to the narrow space of small-diameter special pipelines, it is difficult to design and process the small measurement system in the inner space of special pipelines. This paper proposes a method to design an annular light panoramic view probe to obtain the inner bore image. By automatically tracking the rotation of the helix, the rotation angle of the helix is determined by the image, and the corresponding axial distance is measured by the rope displacement sensor. A suspension guide rail is also designed to solve the problem of the rotation of the glint probe in the special pipeline, so the measurement error of the rifling rotation angle caused by the rotation of the glint probe is eliminated. Through actual measurement, the measurement accuracy of the helix angle is less than 1′, which significantly improves the measurement accuracy of the helix angle of the special pipeline.

Authors

Publication Details

Published
2024-08-05
DOI
https://doi.org/10.1117/12.3038337
Primary Topic
Optical Systems and Laser Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of special pipeline helix angle measurement system based on orifice suspended guide rail

Gangpeng Kong
Optical Systems and Laser Technology
article

Design of special pipeline helix angle measurement system based on orifice suspended guide rail

Gangpeng Kong
article en

Abstract

Due to the narrow space of small-diameter special pipelines, it is difficult to design and process the small measurement system in the inner space of special pipelines. This paper proposes a method to design an annular light panoramic view probe to obtain the inner bore image. By automatically tracking the rotation of the helix, the rotation angle of the helix is determined by the image, and the corresponding axial distance is measured by the rope displacement sensor. A suspension guide rail is also designed to solve the problem of the rotation of the glint probe in the special pipeline, so the measurement error of the rifling rotation angle caused by the rotation of the glint probe is eliminated. Through actual measurement, the measurement accuracy of the helix angle is less than 1′, which significantly improves the measurement accuracy of the helix angle of the special pipeline.

Affordable and clean energy
Openalex Percentile: Top 90%
Optical Systems and Laser Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.