Design and simulation analysis of humanoid lower limb with a parallel compliant actuator

This article presents a design method for humanoid lower limbs with a parallel compliant actuator. The integration of series-parallel main actuators and parallel efficient energy storage mechanisms significantly improves energy efficiency of the humanoid lower limb. The lower limb design is semi-anthropomorphic, with similar mass and mass distribution. Then a three-degree-of-freedom kinematic model of the humanoid lower limbs is established in the Cartesian coordinate system. Besides, The Lagrange equation is utilized to establish the inverse dynamics model, resulting in the derivation of the relationship between joint torque and joint angle. Subsequently, the parameters of elastic elements in the energy storage mechanism are optimized. The energy storage performance of the humanoid lower limbs is simulated in ADAMS. The simulation results validate that the parallel compliant actuation design can improve the energy efficiency of the lower limb, compared with rigid actuation systems.

Authors

Institutions

Publication Details

Published
2024-08-05
DOI
https://doi.org/10.1117/12.3038379
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and simulation analysis of humanoid lower limb with a parallel compliant actuator

Zaojun Fang, Dexin Jiang, Junjun Chen, Yalin Wang et al.
Prosthetics and Rehabilitation Robotics
article

Design and simulation analysis of humanoid lower limb with a parallel compliant actuator

Zaojun Fang, Dexin Jiang, Junjun Chen, Yalin Wang, Bingyang Xiao
article en

Abstract

This article presents a design method for humanoid lower limbs with a parallel compliant actuator. The integration of series-parallel main actuators and parallel efficient energy storage mechanisms significantly improves energy efficiency of the humanoid lower limb. The lower limb design is semi-anthropomorphic, with similar mass and mass distribution. Then a three-degree-of-freedom kinematic model of the humanoid lower limbs is established in the Cartesian coordinate system. Besides, The Lagrange equation is utilized to establish the inverse dynamics model, resulting in the derivation of the relationship between joint torque and joint angle. Subsequently, the parameters of elastic elements in the energy storage mechanism are optimized. The energy storage performance of the humanoid lower limbs is simulated in ADAMS. The simulation results validate that the parallel compliant actuation design can improve the energy efficiency of the lower limb, compared with rigid actuation systems.

Ningbo University (CN), Ningbo Institute of Industrial Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 89%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.