Effect of Protective Eyewear on Physicians’ Lens Exposure during Fluoroscopy

The ICRP 2011 Seoul Statement recommended a reduction in the dose limit for lens exposure to 100 mSv for 5 y and 50 mSv for 1 y. Based on this recommendation, the dose limit for lens exposure was lowered in Japan with the revision of the Ionization Regulations, which took effect in April 2021. In the present study, lens doses were measured during fluoroscopic procedures performed in four departments (Urology, Pediatrics, Gastroenterology, and Orthopedics). Lens doses were measured without protective eyewear for 6 mo (pre-intervention) and then with protective eyewear for the next 6 mo (post-intervention). Monthly doses were collected and lens doses before and after the use of protective eyewear were calculated as the lens dose per unit time. The use of protective eyewear reduced the lens dose per unit time by approximately two thirds. In all departments, the lens dose was slightly lower after than before the intervention. A significant difference was observed in lens doses between the pre- and post-intervention periods in the Urology department. The present results demonstrated the effectiveness of protective eyewear in daily practice. Therefore, the use of protective eyewear is recommended during fluoroscopic procedures.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2024-08-05
DOI
https://doi.org/10.1097/hp.0000000000001875
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Protective Eyewear on Physicians’ Lens Exposure during Fluoroscopy

Takashi Kudo, Takahira Hitomi, Ideguchi Reiko
Health Physics
Radiation Dose and Imaging
article

Effect of Protective Eyewear on Physicians’ Lens Exposure during Fluoroscopy

Takashi Kudo, Takahira Hitomi, Ideguchi Reiko
article en

Abstract

The ICRP 2011 Seoul Statement recommended a reduction in the dose limit for lens exposure to 100 mSv for 5 y and 50 mSv for 1 y. Based on this recommendation, the dose limit for lens exposure was lowered in Japan with the revision of the Ionization Regulations, which took effect in April 2021. In the present study, lens doses were measured during fluoroscopic procedures performed in four departments (Urology, Pediatrics, Gastroenterology, and Orthopedics). Lens doses were measured without protective eyewear for 6 mo (pre-intervention) and then with protective eyewear for the next 6 mo (post-intervention). Monthly doses were collected and lens doses before and after the use of protective eyewear were calculated as the lens dose per unit time. The use of protective eyewear reduced the lens dose per unit time by approximately two thirds. In all departments, the lens dose was slightly lower after than before the intervention. A significant difference was observed in lens doses between the pre- and post-intervention periods in the Urology department. The present results demonstrated the effectiveness of protective eyewear in daily practice. Therefore, the use of protective eyewear is recommended during fluoroscopic procedures.

Health PhysicsVol. 127(6)
Nagasaki University (JP)
Good health and well-being
Openalex Percentile: Top 82%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of Protective Eyewear on Physicians’ Lens Exposure during Fluoroscopy — Takashi Kudo, Takahira Hitomi, et al. · Health Physics (2024) | TGRS Research Map | TGRS