Reliable Stenosis Detection Based on Thrill Waveform Analysis Using Non-Contact Arteriovenous Fistula Imaging

Hemodialysis therapy is an extracorporeal circulation treatment that serves as a substitute for renal function. In Japan, patients receive this efficient four-hour treatment, three times per week, allowing them to maintain a social life nearly equivalent to that of healthy individuals. Before the treatment, two punctures are performed to establish extracorporeal circulation, and a high blood flow rate is essential to ensure efficient therapy. Specialized blood vessels created through arteriovenous fistula (AVF) surgery are utilized to achieve high blood flow rates. Although the AVF allows safe and efficient dialysis treatment, AVF stenosis leads to a serious problem in dialysis. To early detect this abnormal blood flow, auscultation and palpation methods are widely used in hospitals. However, these methods can only provide qualitative judgment of the AVF condition, so the results cannot be shared among other doctors and staff. Additionally, since the conventional methods require contact with the skin, some issues require consideration regarding infection and low reproducibility. In our previous study, we proposed an alternative method for auscultation using non-contact optical imaging technology. This study aims to construct a reliable AVF stenosis detection method using Thrill waveform analysis based on the developed non-contact device to solve the problem with the contact palpation method. This paper demonstrates the performance validation of the non-contact imaging in the normal AVF group (206 total data, 75 patients, mean age: 69.1 years) and in the treatable stenosis group (107 total data, 17 patients, mean age: 70.1 years). The experimental results of the Mann-Whitney U test showed a significant difference (p=0.0002) between the normal and abnormal groups, which indicated the effectiveness of the proposed method as a new possible alternative to palpation.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-08-05
DOI
https://doi.org/10.3390/s24155068
Citations
1
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliable Stenosis Detection Based on Thrill Waveform Analysis Using Non-Contact Arteriovenous Fistula Imaging

Yoshifumi Kawakubo, M. Fukuhara, Takunori Shimazaki, Rumi Iwai et al.
1 citations
Sensors
Central Venous Catheters and Hemodialysis
0.74
article

Reliable Stenosis Detection Based on Thrill Waveform Analysis Using Non-Contact Arteriovenous Fistula Imaging

Yoshifumi Kawakubo, M. Fukuhara, Takunori Shimazaki, Rumi Iwai, Daisuke Anzai, Jaakko Hyry, Takeshi Yokoyama, Hiroki Aono, Shingo Ata
article en
1 citations

Abstract

Hemodialysis therapy is an extracorporeal circulation treatment that serves as a substitute for renal function. In Japan, patients receive this efficient four-hour treatment, three times per week, allowing them to maintain a social life nearly equivalent to that of healthy individuals. Before the treatment, two punctures are performed to establish extracorporeal circulation, and a high blood flow rate is essential to ensure efficient therapy. Specialized blood vessels created through arteriovenous fistula (AVF) surgery are utilized to achieve high blood flow rates. Although the AVF allows safe and efficient dialysis treatment, AVF stenosis leads to a serious problem in dialysis. To early detect this abnormal blood flow, auscultation and palpation methods are widely used in hospitals. However, these methods can only provide qualitative judgment of the AVF condition, so the results cannot be shared among other doctors and staff. Additionally, since the conventional methods require contact with the skin, some issues require consideration regarding infection and low reproducibility. In our previous study, we proposed an alternative method for auscultation using non-contact optical imaging technology. This study aims to construct a reliable AVF stenosis detection method using Thrill waveform analysis based on the developed non-contact device to solve the problem with the contact palpation method. This paper demonstrates the performance validation of the non-contact imaging in the normal AVF group (206 total data, 75 patients, mean age: 69.1 years) and in the treatable stenosis group (107 total data, 17 patients, mean age: 70.1 years). The experimental results of the Mann-Whitney U test showed a significant difference (p=0.0002) between the normal and abnormal groups, which indicated the effectiveness of the proposed method as a new possible alternative to palpation.

SensorsVol. 24(15)
Kyushu University (JP), Nagoya Institute of Technology (JP), Kyushu Dental University (JP), Kyushu University Hospital (JP), Shikoku Central Hospital of the Mutual Aid Association of Public School Teachers (JP), Graduate School of Health Care Sciences, Jikei Institute (JP), Osaka Metropolitan University (JP), Tokyo Metropolitan University (JP)
Good health and well-being
Openalex Percentile: Top 29%
Central Venous Catheters and Hemodialysis
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.