Characterizing dispersion in bovine liver using ARFI-based shear wave rheometry

<i>Background:</i>Dispersion presents both a challenge and a diagnostic opportunity in shear wave elastography (SWE).<i>Shear Wave Rheometry</i>(SWR) is an inversion technique for processing SWE data acquired using an acoustic radiation force impulse (ARFI) excitation. The main advantage of SWR is that it can characterize the shear properties of homogeneous soft media over a wide frequency range. Assumptions associated with SWR include tissue homogeneity, tissue isotropy, and axisymmetry of the ARFI excitation).<i>Objective:</i>Evaluate the validity of the SWR assumptions in ex vivo bovine liver.<i>Approach:</i>SWR was used to measure the shear properties of bovine liver tissue as function of frequency over a large frequency range. Assumptions associated with SWR (tissue homogeneity, tissue isotropy, and axisymmetry of the ARFI excitation) were evaluated through measurements performed at multiple locations and probe orientations. Measurements focused on quantities that would reveal violations of the assumptions.<i>Main results:</i>Measurements of shear properties were obtained over the 25-250 Hz range, and showed a 4-fold increase in shear storage modulus (from 1 to 4 kPa) and over a 10-fold increase in the loss modulus (from 0.2 to 3 kPa) over that decade-wide frequency range. Measurements under different conditions were highly repeatable, and model error was low in all cases.<i>Significance and Conclusion:</i>SWR depends on modeling the ARFI-induced shear wave as a full vector viscoelastic shear wave resulting from an axisymmetric source; it is agnostic to any specific rheological model. Despite this generality, the model makes three main simplifying assumptions. These results show that the modeling assumptions used in SWR are valid in bovine liver over a wide frequency band.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2024-08-05
DOI
https://doi.org/10.1088/2057-1976/ad6b31
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterizing dispersion in bovine liver using ARFI-based shear wave rheometry

Sanjay S. Yengul, Bruno Madore, Paul E. Barbone
Biomedical Physics & Engineering Express
Ultrasound Imaging and Elastography
article

Characterizing dispersion in bovine liver using ARFI-based shear wave rheometry

Sanjay S. Yengul, Bruno Madore, Paul E. Barbone
article en

Abstract

<i>Background:</i>Dispersion presents both a challenge and a diagnostic opportunity in shear wave elastography (SWE).<i>Shear Wave Rheometry</i>(SWR) is an inversion technique for processing SWE data acquired using an acoustic radiation force impulse (ARFI) excitation. The main advantage of SWR is that it can characterize the shear properties of homogeneous soft media over a wide frequency range. Assumptions associated with SWR include tissue homogeneity, tissue isotropy, and axisymmetry of the ARFI excitation).<i>Objective:</i>Evaluate the validity of the SWR assumptions in ex vivo bovine liver.<i>Approach:</i>SWR was used to measure the shear properties of bovine liver tissue as function of frequency over a large frequency range. Assumptions associated with SWR (tissue homogeneity, tissue isotropy, and axisymmetry of the ARFI excitation) were evaluated through measurements performed at multiple locations and probe orientations. Measurements focused on quantities that would reveal violations of the assumptions.<i>Main results:</i>Measurements of shear properties were obtained over the 25-250 Hz range, and showed a 4-fold increase in shear storage modulus (from 1 to 4 kPa) and over a 10-fold increase in the loss modulus (from 0.2 to 3 kPa) over that decade-wide frequency range. Measurements under different conditions were highly repeatable, and model error was low in all cases.<i>Significance and Conclusion:</i>SWR depends on modeling the ARFI-induced shear wave as a full vector viscoelastic shear wave resulting from an axisymmetric source; it is agnostic to any specific rheological model. Despite this generality, the model makes three main simplifying assumptions. These results show that the modeling assumptions used in SWR are valid in bovine liver over a wide frequency band.

Biomedical Physics & Engineering ExpressVol. 10(5)
Boston University (US), Brigham and Women's Hospital (US), Harvard University (US)
Brigham and Women's Hospital, National Institutes of Health, National Institute of Biomedical Imaging and Bioengineering
Openalex Percentile: Top 82%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.