Evaluation of Corrosion Resistance according to Surface treatment of Installed Ammunition Case(ALDC12)
The Remote Control Munition System is a anti-personnel munitions system to replace land mines that are hard to retrieve and can inflict damage on friendly forces and civilians. As operating environments and methods change, quality improvement is necessary to ensure appropriate durability. Therefore, corrosion resistance evaluation was performed according to the surface treatment of ALDC12, the main assembly material. We conduct the potentiodynamic polarization, cyclic corrosion test to perform analysis on corrosion behavior. Additionally, we try to observe the pitting on the surface through SEM analysis. In conclusion, among the three surface treatments, Anodizing surface treatment is judged to be the most suitable for corrosion durability in a field environment.
Authors
- Hye-Min Park (ORCID: https://orcid.org/0000-0002-6776-8749)
- Jong‐Hyeon Lee (ORCID: https://orcid.org/0000-0003-3193-9128)
- Sang‐Bong Lee (ORCID: https://orcid.org/0000-0001-9396-1000)
- Namyoung Yu
Institutions
- Chungnam National University (KR)
- Agency for Defense Development (KR)
- Hanwha Solutions (South Korea) (KR)
Publication Details
- Journal
- Journal of the Korea Institute of Military Science and Technology
- Published
- 2024-08-05
- DOI
- https://doi.org/10.9766/kimst.2024.27.4.457
- Primary Topic
- Electromagnetic Launch and Propulsion Technology
- Type
- article
- Field-Weighted Citation Impact
- 0.00