The Role of a New Hinged Total Knee Arthroplasty System for Use in a Variety of Complex Knee Scenarios: A Case Series

Hinged knee arthroplasties are commonly used in scenarios where there are major ligament deficiencies or bone loss around the knee. They are applicable in native knees with major deformities and during revisions. They can also be used as a salvage procedure after distal femoral resection. The new modular hinged device system, namely the Triathlon Hinge Knee (THK) System (Stryker, Mahwah, New Jersey), reflects the advancements of third-generation design and enhances surgical flexibility by allowing streamlined integration with the Triathlon Total Stabilized (TS) System (Stryker, Mahwah, New Jersey) and the Global Modular Replacement System (GMRS, Stryker, Mahwah, New Jersey). Additionally, the Triathlon Revision Tibial Baseplate (Stryker, Mahwah, New Jersey) has been launched as part of THK and is compatible with the Modular Rotating Hinge (MRH , Stryker, Mahwah, New Jersey) femur, which allows the Revision Baseplate to replace the existing tibial component while leaving the existing MRH Femoral Component in place. The Triathlon Revision Tibial Baseplate enables orthopaedic surgeons to use constrained or hinged prostheses, including both distal and total femoral replacement options, without changing the Tibial Baseplate. This is because the TS, MRH, THK, and GMRS femurs are compatible with the new Triathlon Revision Tibial Baseplate. Additionally, the system can be augmented with metaphyseal cone constructs to help provide a stable foundation for reconstruction. This report explores the application of a new modular hinged device system in various scenarios, starting with (1) complex primary hinged knee arthroplasty, followed by revision hinged knee arthroplasty cases including (2) failed TKA with medial collateral ligament (MCL) dysfunction, (3) severe arthrofibrosis post-TKA, (4) revisions for prosthetic joint infection, (5) extensor mechanism deficiency, and (6) arthrofibrosis with extensor mechanism disruption, concluding with a case of (7) distal femoral arthroplasty for periprosthetic fracture post-failed TKA.

Authors

Institutions

Publication Details

Journal
Surgical Technology Online
Published
2024-09-03
DOI
https://doi.org/10.52198/24.sti.44.os1799
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Role of a New Hinged Total Knee Arthroplasty System for Use in a Variety of Complex Knee Scenarios: A Case Series

Bryan D. Springer, Daniel Hameed, Arthur L. Malkani, Michael A. Mont
Surgical Technology Online
Total Knee Arthroplasty Outcomes
article

The Role of a New Hinged Total Knee Arthroplasty System for Use in a Variety of Complex Knee Scenarios: A Case Series

Bryan D. Springer, Daniel Hameed, Arthur L. Malkani, Michael A. Mont
article en

Abstract

Hinged knee arthroplasties are commonly used in scenarios where there are major ligament deficiencies or bone loss around the knee. They are applicable in native knees with major deformities and during revisions. They can also be used as a salvage procedure after distal femoral resection. The new modular hinged device system, namely the Triathlon Hinge Knee (THK) System (Stryker, Mahwah, New Jersey), reflects the advancements of third-generation design and enhances surgical flexibility by allowing streamlined integration with the Triathlon Total Stabilized (TS) System (Stryker, Mahwah, New Jersey) and the Global Modular Replacement System (GMRS, Stryker, Mahwah, New Jersey). Additionally, the Triathlon Revision Tibial Baseplate (Stryker, Mahwah, New Jersey) has been launched as part of THK and is compatible with the Modular Rotating Hinge (MRH , Stryker, Mahwah, New Jersey) femur, which allows the Revision Baseplate to replace the existing tibial component while leaving the existing MRH Femoral Component in place. The Triathlon Revision Tibial Baseplate enables orthopaedic surgeons to use constrained or hinged prostheses, including both distal and total femoral replacement options, without changing the Tibial Baseplate. This is because the TS, MRH, THK, and GMRS femurs are compatible with the new Triathlon Revision Tibial Baseplate. Additionally, the system can be augmented with metaphyseal cone constructs to help provide a stable foundation for reconstruction. This report explores the application of a new modular hinged device system in various scenarios, starting with (1) complex primary hinged knee arthroplasty, followed by revision hinged knee arthroplasty cases including (2) failed TKA with medial collateral ligament (MCL) dysfunction, (3) severe arthrofibrosis post-TKA, (4) revisions for prosthetic joint infection, (5) extensor mechanism deficiency, and (6) arthrofibrosis with extensor mechanism disruption, concluding with a case of (7) distal femoral arthroplasty for periprosthetic fracture post-failed TKA.

Surgical Technology OnlineVol. 44
University of Louisville (US)
Openalex Percentile: Top 79%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.