Comparative Study of Transformer Robustness for Multiple Particle Tracking Without Clutter

The tracking of multiple particles in image se-quences is challenged by the stochastic nature of displacements, particles detection errors, and the combinatorial explosion of all possible trajectories. As such, extensive work has focused on the modeling of noisy trajectories to try and predict the most likely trajectory-to-measurements associations. Recently, transformers have been shown to significantly accelerate the evaluation of probabilistic models for the system dynamics and detection clutter generated from false positives. However, little work has focused on clutter-free scenarios with multiple particles moving erratically, where the challenge resides not in the model complexity, but in the combinatorial burden of considering all possible trajectory-to-measurements associations. This is a common occurrence in fluorescence microscopy at low framerate. This paper offers a proof-of-concept study of the benefit of the transformer architecture in such scenarios through the simulation of two-particle-systems undergoing Brownian motion. Specifically, we designed a transformer for this estimation task and compared it with the Multiple Hypothesis Tracker (MHT), the optimal estimator when all trajectory-to-measurement associ-ations can be computed. We first show increased robustness of the transformer against erratic displacements over long sequences, with significantly lower computational complexity than MHT. Then, we show that while the transformer requires very little training to significantly outperform MHT on long sequences, it cannot match the theoretically optimal performances of MHT on short sequences even with extensive training. Hence, our work motivates the broader application of transformers in high-SNR sequences and opens the way to the development of frugal methods thanks to the combination of both statistical and neural network frameworks for particle tracking.

Authors

Institutions

Publication Details

Published
2024-08-26
DOI
https://doi.org/10.23919/eusipco63174.2024.10715042
Citations
1
Primary Topic
Electrohydrodynamics and Fluid Dynamics
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Study of Transformer Robustness for Multiple Particle Tracking Without Clutter

Piyush Mishra, Philippe Roudot
1 citations
Electrohydrodynamics and Fluid Dynamics
0.21
article

Comparative Study of Transformer Robustness for Multiple Particle Tracking Without Clutter

Piyush Mishra, Philippe Roudot
article en
1 citations

Abstract

The tracking of multiple particles in image se-quences is challenged by the stochastic nature of displacements, particles detection errors, and the combinatorial explosion of all possible trajectories. As such, extensive work has focused on the modeling of noisy trajectories to try and predict the most likely trajectory-to-measurements associations. Recently, transformers have been shown to significantly accelerate the evaluation of probabilistic models for the system dynamics and detection clutter generated from false positives. However, little work has focused on clutter-free scenarios with multiple particles moving erratically, where the challenge resides not in the model complexity, but in the combinatorial burden of considering all possible trajectory-to-measurements associations. This is a common occurrence in fluorescence microscopy at low framerate. This paper offers a proof-of-concept study of the benefit of the transformer architecture in such scenarios through the simulation of two-particle-systems undergoing Brownian motion. Specifically, we designed a transformer for this estimation task and compared it with the Multiple Hypothesis Tracker (MHT), the optimal estimator when all trajectory-to-measurement associ-ations can be computed. We first show increased robustness of the transformer against erratic displacements over long sequences, with significantly lower computational complexity than MHT. Then, we show that while the transformer requires very little training to significantly outperform MHT on long sequences, it cannot match the theoretically optimal performances of MHT on short sequences even with extensive training. Hence, our work motivates the broader application of transformers in high-SNR sequences and opens the way to the development of frugal methods thanks to the combination of both statistical and neural network frameworks for particle tracking.

Centre National de la Recherche Scientifique (FR), Aix-Marseille Université (FR), Château Gombert (FR), Institut Fresnel (FR), Institut de Mathématiques de Marseille (FR), Centrale Méditerranée (FR), Institut Polytechnique de Bordeaux (FR)
Agence Nationale de la Recherche
Affordable and clean energy
Openalex Percentile: Top 51%
Electrohydrodynamics and Fluid Dynamics
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.