Unsupervised Bayesian generation of synthetic CT from CBCT using patient‐specific score‐based prior

The proposed method is in an unsupervised framework that utilizes a patient-specific score-based model as the image prior alongside a customized total variation (TV) regularization to enforce coherence across different transverse slices. The score-based model is unconditionally trained using the same patient's planning CT (pCT) images to characterize the manifold of CT-quality images and capture the unique anatomical information of the specific patient. The efficacy of the proposed method was assessed on images from anatomical sites including head and neck (H&N) cancer, pancreatic cancer, and lung cancer. The performance of the proposed CBCT correction method was evaluated using quantitative metrics including mean absolute error (MAE), peak signal-to-noise ratio (PSNR), and normalized cross-correlation (NCC). Additionally, the proposed algorithm was benchmarked against two other unsupervised diffusion model-based CBCT correction algorithms.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2024-12-12
DOI
https://doi.org/10.1002/mp.17572
Citations
7
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
4.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Unsupervised Bayesian generation of synthetic CT from CBCT using patient‐specific score‐based prior

Jacob G. Scott, Richard L. J. Qiu, Tonghe Wang, David S. Yu et al.
7 citations
Medical Physics
Advanced Radiotherapy Techniques
4.25
article

Unsupervised Bayesian generation of synthetic CT from CBCT using patient‐specific score‐based prior

Jacob G. Scott, Richard L. J. Qiu, Tonghe Wang, David S. Yu, Kailin Yang, Aparna H. Kesarwala, Chih‐Wei Chang, Xiaofeng Yang, Yuan Gao, Junbo Peng
article en
7 citations

Abstract

The proposed method is in an unsupervised framework that utilizes a patient-specific score-based model as the image prior alongside a customized total variation (TV) regularization to enforce coherence across different transverse slices. The score-based model is unconditionally trained using the same patient's planning CT (pCT) images to characterize the manifold of CT-quality images and capture the unique anatomical information of the specific patient. The efficacy of the proposed method was assessed on images from anatomical sites including head and neck (H&N) cancer, pancreatic cancer, and lung cancer. The performance of the proposed CBCT correction method was evaluated using quantitative metrics including mean absolute error (MAE), peak signal-to-noise ratio (PSNR), and normalized cross-correlation (NCC). Additionally, the proposed algorithm was benchmarked against two other unsupervised diffusion model-based CBCT correction algorithms.

Medical PhysicsVol. 52(4)
Cleveland Clinic (US), Memorial Sloan Kettering Cancer Center (US), Emory University (US)
LUNGevity Foundation, Radiological Society of North America, National Institutes of Health
Openalex Percentile: Top 6%
Advanced Radiotherapy Techniques
4.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Unsupervised Bayesian generation of synthetic CT from CBCT using patient‐specific score‐based prior — Jacob G. Scott, Richard L. J. Qiu, et al. · Medical Physics (2024) | TGRS Research Map | TGRS