Reduction of Motion Artifacts in Cardiorespiratory Vital Signs as Oxygen Saturation and Non-Invasive Blood Pressure Through Redundant Denoising and Adaptive Filtering Methods for Wearable Healthcare Monitoring Systems

Abstract Background and objective Chronic cardiovascular diseases have motivated the development of wearable systems capable of continuously monitoring physiological variables such as oxygen saturation (SpO $$_2$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mmultiscripts> <mml:mrow/> <mml:mn>2</mml:mn> <mml:mrow/> </mml:mmultiscripts> </mml:math> ) and non-invasive blood pressure (NIBP). However, motion artifacts remain one of the main limitations affecting the reliability of these measurements in ambulatory environments. This article presents a novel framework for motion artifact reduction in photoplethysmography (PPG) and NIBP signals based on redundant sensing, inertial measurements, ECG-guided temporal synchrony, and multichannel signal processing. Methods The proposed framework combines independent component analysis and recursive least-squares adaptive filtering to separate physiological information from motion-induced interference. Performance was compared with conventional finite impulse response (FIR) filtering and wavelet shrinkage (WS) methods using signal-to-noise ratio (SNR), weighted distortion assessment (WDA), oxygen saturation estimation, and blood pressure estimation metrics. Results The proposed method achieved statistically significant improvements in signal quality and physiological parameter estimation. Average SNR improved from $$-5.93\pm 5.05$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mo>-</mml:mo> <mml:mn>5.93</mml:mn> <mml:mo>±</mml:mo> <mml:mn>5.05</mml:mn> </mml:mrow> </mml:math> dB to $$-3.43\pm 2.02$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mo>-</mml:mo> <mml:mn>3.43</mml:mn> <mml:mo>±</mml:mo> <mml:mn>2.02</mml:mn> </mml:mrow> </mml:math> dB in the red PPG channel ( $$p=0.02$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mi>p</mml:mi> <mml:mo>=</mml:mo> <mml:mn>0.02</mml:mn> </mml:mrow> </mml:math> ), while the WDA index increased from 0.48 to 0.73. Oxygen saturation estimation improved from $$80.87\pm 9.09\%$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>80.87</mml:mn> <mml:mo>±</mml:mo> <mml:mn>9.09</mml:mn> <mml:mo>%</mml:mo> </mml:mrow> </mml:math> in motion-contaminated signals to $$94.16\pm 2.72\%$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>94.16</mml:mn> <mml:mo>±</mml:mo> <mml:mn>2.72</mml:mn> <mml:mo>%</mml:mo> </mml:mrow> </mml:math> after denoising ( $$p=0.04$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mi>p</mml:mi> <mml:mo>=</mml:mo> <mml:mn>0.04</mml:mn> </mml:mrow> </mml:math> ), approaching resting measurements ( $$95.23\pm 2.31\%$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>95.23</mml:mn> <mml:mo>±</mml:mo> <mml:mn>2.31</mml:mn> <mml:mo>%</mml:mo> </mml:mrow> </mml:math> ). For NIBP signals, statistically significant improvements were also observed ( $$p=0.045$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mi>p</mml:mi> <mml:mo>=</mml:mo> <mml:mn>0.045</mml:mn> </mml:mrow> </mml:math> ), particularly for systolic pressure estimation, although diastolic pressure remained affected by residual motion-related distortions. Conclusions The proposed framework improves the robustness of wearable PPG and NIBP monitoring under motion conditions through the combined use of sensor redundancy, ECG-guided temporal coupling, inertial measurements, and adaptive multichannel signal processing. The results demonstrate significant improvements in signal quality and physiological parameter estimation compared with conventional denoising approaches, supporting the potential use of the method in ambulatory cardiovascular monitoring applications.

Authors

Institutions

Publication Details

Journal
Cardiovascular Engineering and Technology
Published
2026-08-03
DOI
https://doi.org/10.1007/s13239-026-00850-0
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reduction of Motion Artifacts in Cardiorespiratory Vital Signs as Oxygen Saturation and Non-Invasive Blood Pressure Through Redundant Denoising and Adaptive Filtering Methods for Wearable Healthcare Monitoring Systems

Fabián Andrés Castaño, Alher Mauricio Hernández
Cardiovascular Engineering and Technology
Non-Invasive Vital Sign Monitoring
article

Reduction of Motion Artifacts in Cardiorespiratory Vital Signs as Oxygen Saturation and Non-Invasive Blood Pressure Through Redundant Denoising and Adaptive Filtering Methods for Wearable Healthcare Monitoring Systems

Fabián Andrés Castaño, Alher Mauricio Hernández
article en

Abstract

Abstract Background and objective Chronic cardiovascular diseases have motivated the development of wearable systems capable of continuously monitoring physiological variables such as oxygen saturation (SpO $$_2$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mmultiscripts> <mml:mrow/> <mml:mn>2</mml:mn> <mml:mrow/> </mml:mmultiscripts> </mml:math> ) and non-invasive blood pressure (NIBP). However, motion artifacts remain one of the main limitations affecting the reliability of these measurements in ambulatory environments. This article presents a novel framework for motion artifact reduction in photoplethysmography (PPG) and NIBP signals based on redundant sensing, inertial measurements, ECG-guided temporal synchrony, and multichannel signal processing. Methods The proposed framework combines independent component analysis and recursive least-squares adaptive filtering to separate physiological information from motion-induced interference. Performance was compared with conventional finite impulse response (FIR) filtering and wavelet shrinkage (WS) methods using signal-to-noise ratio (SNR), weighted distortion assessment (WDA), oxygen saturation estimation, and blood pressure estimation metrics. Results The proposed method achieved statistically significant improvements in signal quality and physiological parameter estimation. Average SNR improved from $$-5.93\pm 5.05$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mo>-</mml:mo> <mml:mn>5.93</mml:mn> <mml:mo>±</mml:mo> <mml:mn>5.05</mml:mn> </mml:mrow> </mml:math> dB to $$-3.43\pm 2.02$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mo>-</mml:mo> <mml:mn>3.43</mml:mn> <mml:mo>±</mml:mo> <mml:mn>2.02</mml:mn> </mml:mrow> </mml:math> dB in the red PPG channel ( $$p=0.02$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mi>p</mml:mi> <mml:mo>=</mml:mo> <mml:mn>0.02</mml:mn> </mml:mrow> </mml:math> ), while the WDA index increased from 0.48 to 0.73. Oxygen saturation estimation improved from $$80.87\pm 9.09\%$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>80.87</mml:mn> <mml:mo>±</mml:mo> <mml:mn>9.09</mml:mn> <mml:mo>%</mml:mo> </mml:mrow> </mml:math> in motion-contaminated signals to $$94.16\pm 2.72\%$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>94.16</mml:mn> <mml:mo>±</mml:mo> <mml:mn>2.72</mml:mn> <mml:mo>%</mml:mo> </mml:mrow> </mml:math> after denoising ( $$p=0.04$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mi>p</mml:mi> <mml:mo>=</mml:mo> <mml:mn>0.04</mml:mn> </mml:mrow> </mml:math> ), approaching resting measurements ( $$95.23\pm 2.31\%$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>95.23</mml:mn> <mml:mo>±</mml:mo> <mml:mn>2.31</mml:mn> <mml:mo>%</mml:mo> </mml:mrow> </mml:math> ). For NIBP signals, statistically significant improvements were also observed ( $$p=0.045$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mi>p</mml:mi> <mml:mo>=</mml:mo> <mml:mn>0.045</mml:mn> </mml:mrow> </mml:math> ), particularly for systolic pressure estimation, although diastolic pressure remained affected by residual motion-related distortions. Conclusions The proposed framework improves the robustness of wearable PPG and NIBP monitoring under motion conditions through the combined use of sensor redundancy, ECG-guided temporal coupling, inertial measurements, and adaptive multichannel signal processing. The results demonstrate significant improvements in signal quality and physiological parameter estimation compared with conventional denoising approaches, supporting the potential use of the method in ambulatory cardiovascular monitoring applications.

Cardiovascular Engineering and Technology
Universidad de Antioquia (CO)
Universidad de Antioquia
Zero hunger
Openalex Percentile: Top 100%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.