Measurement of the absolute efficiency of the X-ARAPUCA photon detector for the DUNE Far Detector 1

Abstract The DUNE far detector has been designed to detect photons and electrons generated by the charged products of the interaction of neutrinos with a massive liquid argon (LAr) target. The photon detection system (PDS) of the first DUNE far detector (FD1) is composed of 6000 photon detection units, named X-ARAPUCA . The detection of the prompt light pulse generated by the particle energy release in LAr will complement and boost the DUNE LAr Time Projection Chamber. It will improve the non-beam events tagging and enable at low energies the trigger and the calorimetry of the supernova neutrinos. The X-ARAPUCA is an assembly of several components. Its photon detection efficiency (PDE) depends on the design of the assembly, on the grade of the individual components and on their coupling. The X-ARAPUCA PDE is one of the leading parameters for the PDS sensitivity, that in turn determines the sensitivity of the DUNE for the detection of core-collapse supernova within the galaxy and for nucleon decay searches. In this work we present the final assessment of the absolute PDE of the FD1 X-ARAPUCA baseline design, measured in two laboratories with independent methods and setups. Preliminary results were reported in Palomares (JINST 18(02):C02064, https://doi.org/10.1088/1748-0221/18/02/C02064 , 2023). One hundred sixty units of these X-ARAPUCA devices have been deployed in the NP04 facility at the CERN Neutrino Platform, the 1:20 scale FD1 prototype, and will be operated during the year 2024. The assessed value of the PDE is a key parameter both in the NP04 and in the DUNE analysis and reconstruction studies.

Authors

Institutions

Publication Details

Journal
The European Physical Journal C
Published
2024-10-07
DOI
https://doi.org/10.1140/epjc/s10052-024-13393-2
Citations
4
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
2.64

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of the absolute efficiency of the X-ARAPUCA photon detector for the DUNE Far Detector 1

C. Cuesta, A. Verdugo de Osa, C. Cattadori, L. Pérez-Molina et al.
4 citations
The European Physical Journal C
Particle Detector Development and Performance
2.64
article

Measurement of the absolute efficiency of the X-ARAPUCA photon detector for the DUNE Far Detector 1

C. Cuesta, A. Verdugo de Osa, C. Cattadori, L. Pérez-Molina, H. Vieira de Souza, Christian Massari, C. Gotti, D. Warner, D. Güffanti, C. Brizzolari, A. de la Torre Rojo, C. Palomares, S. Manthey Corchado, L. Meazza, F. Terranova, R. Álvarez-Garrote, I. Gil‐Botella, I. Martín, A.A. Machado, A. Canto, E. Segreto, E. Calvo
article en
4 citations

Abstract

Abstract The DUNE far detector has been designed to detect photons and electrons generated by the charged products of the interaction of neutrinos with a massive liquid argon (LAr) target. The photon detection system (PDS) of the first DUNE far detector (FD1) is composed of 6000 photon detection units, named X-ARAPUCA . The detection of the prompt light pulse generated by the particle energy release in LAr will complement and boost the DUNE LAr Time Projection Chamber. It will improve the non-beam events tagging and enable at low energies the trigger and the calorimetry of the supernova neutrinos. The X-ARAPUCA is an assembly of several components. Its photon detection efficiency (PDE) depends on the design of the assembly, on the grade of the individual components and on their coupling. The X-ARAPUCA PDE is one of the leading parameters for the PDS sensitivity, that in turn determines the sensitivity of the DUNE for the detection of core-collapse supernova within the galaxy and for nucleon decay searches. In this work we present the final assessment of the absolute PDE of the FD1 X-ARAPUCA baseline design, measured in two laboratories with independent methods and setups. Preliminary results were reported in Palomares (JINST 18(02):C02064, https://doi.org/10.1088/1748-0221/18/02/C02064 , 2023). One hundred sixty units of these X-ARAPUCA devices have been deployed in the NP04 facility at the CERN Neutrino Platform, the 1:20 scale FD1 prototype, and will be operated during the year 2024. The assessed value of the PDE is a key parameter both in the NP04 and in the DUNE analysis and reconstruction studies.

The European Physical Journal CVol. 84(10)
Universidad Complutense de Madrid (ES), Universidade Estadual de Campinas (UNICAMP) (BR), Laboratoire AstroParticule et Cosmologie (FR), Istituto Nazionale di Fisica Nucleare, Sezione di Milano Bicocca (IT), Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (ES), University of Milano-Bicocca (IT), University of Naples Federico II (IT)
Fundación BBVA, European Commission, Banco Bilbao Vizcaya Argentaria, Agencia Estatal de Investigación
Affordable and clean energy
Openalex Percentile: Top 8%
Particle Detector Development and Performance
2.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.