Reproducibility Made Easy: A Tool for Methodological Transparency and Efficient Standardized Reporting Based on the Proposed MRSinMRS Consensus

Recent expert consensus publications have highlighted the issue of poor reproducibility in magnetic resonance spectroscopy (MRS) studies, mainly due to the lack of standardized reporting criteria, which affects their clinical applicability. To combat this, guidelines for minimum reporting standards (MRSinMRS) were introduced to aid journal editors and reviewers in ensuring the comprehensive documentation of essential MRS study parameters. Despite these efforts, the implementation of MRSinMRS standards has been slow, attributed to the diverse nomenclature used by different vendors, the variety of raw MRS data formats, and the absence of appropriate software tools for identifying and reporting necessary parameters. To overcome this obstacle, we have developed the REproducibility Made Easy (REMY) standalone toolbox. REMY software supports a range of MRS data formats from major vendors like GE (.7), Siemens (.ima, .rda, .dcm), Philips (.spar/.sdat), and Bruker (.method), and MRS-NIfTI (.nii/nii.gz/.json) files facilitating easy data import and export through a user-friendly interface. REMY employs external libraries such as spec2nii and pymapVBVD to accurately read and process these diverse data formats, translating complex header information into a comprehensive structure that adheres to consensus reporting standards, thereby ensuring compatibility and ease of use for researchers in generating reproducible MRS research outputs. Users can select and import datasets, choose the appropriate vendor and data format, and then generate an MRSinMRS table, log file, and methodological documents in both Latex and PDF formats by just clicking one button. No coding knowledge is required, making the tool accessible to a wider range of users, including researchers and clinicians without programming expertise. This eliminates technical challenges related to data formatting and reporting. REMY effectively populated key sections of the MRSinMRS table with data from all supported file types. Accurate generation of hardware parameters including field strength, manufacturer, and scanner software version were demonstrated. However, it could not input data for RF coil and additional hardware information due to their absence in the files. For the acquisition section, REMY accurately read and populated fields for the pulse sequence name, nominal voxel size, repetition time (TR), echo time (TE), number of acquisitions/excitations/shots, spectral width (Hz), and number of spectral points, significantly contributing to the completion of the "Acquisition" fields of the table. Furthermore, REMY generates a boilerplate methods text section for manuscripts. The use of REMY will facilitate more widespread adoption of the MRSinMRS checklist within the MRS community, making it easier to write and report acquisition parameters effectively.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2025-05-02
DOI
https://doi.org/10.1002/nbm.70039
Citations
1
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reproducibility Made Easy: A Tool for Methodological Transparency and Efficient Standardized Reporting Based on the Proposed MRSinMRS Consensus

Aaron T. Gudmundson, Georg Oeltzschner, Dunja Simičić, Antonia Šušnjar et al.
1 citations
NMR in Biomedicine
Advanced MRI Techniques and Applications
1.36
article

Reproducibility Made Easy: A Tool for Methodological Transparency and Efficient Standardized Reporting Based on the Proposed MRSinMRS Consensus

Aaron T. Gudmundson, Georg Oeltzschner, Dunja Simičić, Antonia Šušnjar, Antonia Kaiser, Alexander Lin, Gianna Nossa
article en
1 citations

Abstract

Recent expert consensus publications have highlighted the issue of poor reproducibility in magnetic resonance spectroscopy (MRS) studies, mainly due to the lack of standardized reporting criteria, which affects their clinical applicability. To combat this, guidelines for minimum reporting standards (MRSinMRS) were introduced to aid journal editors and reviewers in ensuring the comprehensive documentation of essential MRS study parameters. Despite these efforts, the implementation of MRSinMRS standards has been slow, attributed to the diverse nomenclature used by different vendors, the variety of raw MRS data formats, and the absence of appropriate software tools for identifying and reporting necessary parameters. To overcome this obstacle, we have developed the REproducibility Made Easy (REMY) standalone toolbox. REMY software supports a range of MRS data formats from major vendors like GE (.7), Siemens (.ima, .rda, .dcm), Philips (.spar/.sdat), and Bruker (.method), and MRS-NIfTI (.nii/nii.gz/.json) files facilitating easy data import and export through a user-friendly interface. REMY employs external libraries such as spec2nii and pymapVBVD to accurately read and process these diverse data formats, translating complex header information into a comprehensive structure that adheres to consensus reporting standards, thereby ensuring compatibility and ease of use for researchers in generating reproducible MRS research outputs. Users can select and import datasets, choose the appropriate vendor and data format, and then generate an MRSinMRS table, log file, and methodological documents in both Latex and PDF formats by just clicking one button. No coding knowledge is required, making the tool accessible to a wider range of users, including researchers and clinicians without programming expertise. This eliminates technical challenges related to data formatting and reporting. REMY effectively populated key sections of the MRSinMRS table with data from all supported file types. Accurate generation of hardware parameters including field strength, manufacturer, and scanner software version were demonstrated. However, it could not input data for RF coil and additional hardware information due to their absence in the files. For the acquisition section, REMY accurately read and populated fields for the pulse sequence name, nominal voxel size, repetition time (TR), echo time (TE), number of acquisitions/excitations/shots, spectral width (Hz), and number of spectral points, significantly contributing to the completion of the "Acquisition" fields of the table. Furthermore, REMY generates a boilerplate methods text section for manuscripts. The use of REMY will facilitate more widespread adoption of the MRSinMRS checklist within the MRS community, making it easier to write and report acquisition parameters effectively.

NMR in BiomedicineVol. 38(6)
Brigham and Women's Hospital (US), Kennedy Krieger Institute (US), Harvard University (US), Johns Hopkins University (US), Purdue University West Lafayette (US), Massachusetts General Hospital (US), Athinoula A. Martinos Center for Biomedical Imaging (US), Centre d'Imagerie BioMedicale (CH), École Polytechnique Fédérale de Lausanne (CH), University of Baltimore (US)
Purdue University, Amsterdam University Medical Centers, École Polytechnique Fédérale de Lausanne, Centre d'Imagerie BioMédicale, National Institutes of Health
Openalex Percentile: Top 25%
Advanced MRI Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.