Heat flux partition based on onset of significant void

The thermal log-law Θ+(y+)=β+2.12log(y+) is valid in flow boiling with a value of β that evolves as the flow develops. Using a multiphase flow cross-literature database, this constant is shown to be βOSV=−7 at the point of onset of significant void (OSV). This means that at the OSV the liquid is at saturation temperature up to y+≃30. The OSV predictions using this model have a similar mean average error as the Saha and Zuber 1974 correlation for one less fitted constant for channel, pipe and annular flows for pressure from 1 to 147 bar and Peclet numbers from 3.5⋅103 to 4⋅105. This model is used to build a heat flux partitioning (HFP) inspired from system-scale codes (Lahey 1978). It predicts the distribution of the heat flux between the liquid phase and the evaporation term when the total heat flux is known. It does not give information on the total heat flux as a function of wall temperature and cannot be used to draw a boiling curve. In imposed flux conditions, this partition provides more coherent flux distribution between the evaporation and liquid terms than Kurul and Podowski (1990) based approaches and improves void fraction predictions in high-subcooling regions on the DEBORA database (Garnier et al. 2001) and on experiments by Bartolomei and Chanturiya (1967) and Bartolomei et al. (1982). When the wall temperature is imposed, it must be coupled with an empirical boiling total heat flux correlation to replace a traditional HFP. The prediction of the total heat flux is then as good as that of the correlation.

Authors

Institutions

Publication Details

Journal
International Journal of Multiphase Flow
Published
2024-08-31
DOI
https://doi.org/10.1016/j.ijmultiphaseflow.2024.104972
Citations
3
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.64
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heat flux partition based on onset of significant void

Catherine Colin, Antoine Gerschenfeld, Corentin Reiss
3 citations
International Journal of Multiphase Flow
Heat Transfer and Boiling Studies
0.64
article

Heat flux partition based on onset of significant void

Catherine Colin, Antoine Gerschenfeld, Corentin Reiss
article en
3 citations

Abstract

The thermal log-law Θ+(y+)=β+2.12log(y+) is valid in flow boiling with a value of β that evolves as the flow develops. Using a multiphase flow cross-literature database, this constant is shown to be βOSV=−7 at the point of onset of significant void (OSV). This means that at the OSV the liquid is at saturation temperature up to y+≃30. The OSV predictions using this model have a similar mean average error as the Saha and Zuber 1974 correlation for one less fitted constant for channel, pipe and annular flows for pressure from 1 to 147 bar and Peclet numbers from 3.5⋅103 to 4⋅105. This model is used to build a heat flux partitioning (HFP) inspired from system-scale codes (Lahey 1978). It predicts the distribution of the heat flux between the liquid phase and the evaporation term when the total heat flux is known. It does not give information on the total heat flux as a function of wall temperature and cannot be used to draw a boiling curve. In imposed flux conditions, this partition provides more coherent flux distribution between the evaporation and liquid terms than Kurul and Podowski (1990) based approaches and improves void fraction predictions in high-subcooling regions on the DEBORA database (Garnier et al. 2001) and on experiments by Bartolomei and Chanturiya (1967) and Bartolomei et al. (1982). When the wall temperature is imposed, it must be coupled with an empirical boiling total heat flux correlation to replace a traditional HFP. The prediction of the total heat flux is then as good as that of the correlation.

International Journal of Multiphase FlowVol. 181
Centre National de la Recherche Scientifique (FR), Université Toulouse III - Paul Sabatier (FR), Université Fédérale de Toulouse Midi-Pyrénées (FR), Institut National Polytechnique de Toulouse (FR), Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), Université Paris-Saclay (FR), Institut de Mécanique des Fluides de Toulouse (FR), CEA Paris-Saclay (FR)
Affordable and clean energy
Openalex Percentile: Top 38%
Heat Transfer and Boiling Studies
0.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.