Non linear seismic analysis of charge/discharge machine
The Magnox Nuclear Power Station at Latina has undergone a design re-appraisal under revised seismic loadings. As part of this exercise the charge/discharge machine (CDM) has been analysed in three stages. Initially, a conservative, linear response spectrum analysis was carried out to assess the global response. This was followed by more detailed static stress analysis of structural members and components. The linear analysis necessitated a number of simplifying assumptions which on one hand are over-conservative and on the other lead to unrealistic dynamic behaviour. This paper describes the third phase of the analysis where the non-linear features of the CDM were taken into account.
Authors
- Maria Rossella Nobile (ORCID: https://orcid.org/0000-0002-7647-4160)
- M. Dostal (ORCID: https://orcid.org/0000-0002-5507-7748)
- V.M. Trbojevic
Institutions
- Enel (Poland) (PL)
- National Nuclear Corporation (United Kingdom) (GB)
Publication Details
- Published
- 2026-01-14
- DOI
- https://doi.org/10.1201/9781003763253-80
- Primary Topic
- Oil and Gas Production Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00