Shear-Stress-Dependent Viscous Properties of Hyaluronic-Based Lubricants
<b>Background/Objectives</b>: The physical properties of topical eyedrop formulations used for the treatment of dry-eye disease play an important role in the lubrication of the ocular surface. In the present study, we investigate the shear-stress-dependent viscous properties of seven different commercially available lubricants using a novel optical rheometer for accurate analysis of the viscosity of liquid samples. In addition, the viscosity of natural tears was studied. <b>Methods</b>: Viscosity measurements were performed using Fluidicam RHEO technology (FORMULACTION, Toulouse, France), an automated optical rheometer combining microfluidic and imaging technologies. Measurements were conducted at a temperature of 34 °C and at shear rates ranging from 3000 s<sup>-1</sup> to 30,000 s<sup>-1</sup> to mimic conditions during eye blinking. <b>Results</b>: Natural tears showed minimal change in viscosity in response to changes in shear stress, with viscosity values of 0.91 mPa·s at 3000 s<sup>-1</sup> and 0.80 mPa·s at 30,000 s<sup>-1</sup>. Among the artificial tear formulations, Thealoz<sup>®</sup> Duo had the lowest viscosity (2.62 ± 0.01 mPa·s at 3000 s<sup>-1</sup>), followed by Ivizia<sup>®</sup> (2.42 ± 0.02 mPa·s), Hylo Comod<sup>®</sup> (3.69 ± 0.01 mPa·s), Hylo Parin<sup>®</sup> (3.87 ± 0.01 mPa·s), Xailin HA<sup>®</sup> (4.73 ± 0.02 mPa·s), Vismed<sup>®</sup> (5.42 ± 0.02 mPa·s), and Systane Hydration<sup>®</sup> (7.76 ± 0.1 mPa·s). <b>Conclusions</b>: This study demonstrates that commercially available ocular lubricants exhibit varying degrees of shear-thinning behavior, a finding that is clinically relevant for their performance on the ocular surface. Formulations containing low-molecular-weight hyaluronic acid, such as Thealoz<sup>®</sup> Duo, exhibited viscosity values closest to those of natural tears at the measured shear rates.
Authors
- Doreen Schmidl (ORCID: https://orcid.org/0000-0001-5664-7768)
- Leopold F. Schmetterer (ORCID: https://orcid.org/0000-0002-7189-1707)
- Gerhard Garhöfer (ORCID: https://orcid.org/0000-0001-5547-5669)
- Ulrich Graf (ORCID: https://orcid.org/0009-0005-6935-9606)
Institutions
- Nanyang Technological University (SG)
- Singapore National Eye Center (SG)
- Singapore Eye Research Institute (SG)
- Fondation Ophtalmologique Adolphe de Rothschild (FR)
- Duke-NUS Medical School (SG)
- He Eye Hospital (CN)
- Medical University of Vienna (AT)
Publication Details
- Journal
- Journal of Clinical Medicine
- Published
- 2025-12-10
- DOI
- https://doi.org/10.3390/jcm14248753
- Citations
- 2
- Primary Topic
- Gear and Bearing Dynamics Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.71