Shear-Stress-Dependent Viscous Properties of Hyaluronic-Based Lubricants

<b>Background/Objectives</b>: The physical properties of topical eyedrop formulations used for the treatment of dry-eye disease play an important role in the lubrication of the ocular surface. In the present study, we investigate the shear-stress-dependent viscous properties of seven different commercially available lubricants using a novel optical rheometer for accurate analysis of the viscosity of liquid samples. In addition, the viscosity of natural tears was studied. <b>Methods</b>: Viscosity measurements were performed using Fluidicam RHEO technology (FORMULACTION, Toulouse, France), an automated optical rheometer combining microfluidic and imaging technologies. Measurements were conducted at a temperature of 34 °C and at shear rates ranging from 3000 s<sup>-1</sup> to 30,000 s<sup>-1</sup> to mimic conditions during eye blinking. <b>Results</b>: Natural tears showed minimal change in viscosity in response to changes in shear stress, with viscosity values of 0.91 mPa·s at 3000 s<sup>-1</sup> and 0.80 mPa·s at 30,000 s<sup>-1</sup>. Among the artificial tear formulations, Thealoz<sup>®</sup> Duo had the lowest viscosity (2.62 ± 0.01 mPa·s at 3000 s<sup>-1</sup>), followed by Ivizia<sup>®</sup> (2.42 ± 0.02 mPa·s), Hylo Comod<sup>®</sup> (3.69 ± 0.01 mPa·s), Hylo Parin<sup>®</sup> (3.87 ± 0.01 mPa·s), Xailin HA<sup>®</sup> (4.73 ± 0.02 mPa·s), Vismed<sup>®</sup> (5.42 ± 0.02 mPa·s), and Systane Hydration<sup>®</sup> (7.76 ± 0.1 mPa·s). <b>Conclusions</b>: This study demonstrates that commercially available ocular lubricants exhibit varying degrees of shear-thinning behavior, a finding that is clinically relevant for their performance on the ocular surface. Formulations containing low-molecular-weight hyaluronic acid, such as Thealoz<sup>®</sup> Duo, exhibited viscosity values closest to those of natural tears at the measured shear rates.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-12-10
DOI
https://doi.org/10.3390/jcm14248753
Citations
2
Primary Topic
Gear and Bearing Dynamics Analysis
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shear-Stress-Dependent Viscous Properties of Hyaluronic-Based Lubricants

Doreen Schmidl, Leopold F. Schmetterer, Gerhard Garhöfer, Ulrich Graf
2 citations
Journal of Clinical Medicine
Gear and Bearing Dynamics Analysis
0.71
article

Shear-Stress-Dependent Viscous Properties of Hyaluronic-Based Lubricants

Doreen Schmidl, Leopold F. Schmetterer, Gerhard Garhöfer, Ulrich Graf
article en
2 citations

Abstract

<b>Background/Objectives</b>: The physical properties of topical eyedrop formulations used for the treatment of dry-eye disease play an important role in the lubrication of the ocular surface. In the present study, we investigate the shear-stress-dependent viscous properties of seven different commercially available lubricants using a novel optical rheometer for accurate analysis of the viscosity of liquid samples. In addition, the viscosity of natural tears was studied. <b>Methods</b>: Viscosity measurements were performed using Fluidicam RHEO technology (FORMULACTION, Toulouse, France), an automated optical rheometer combining microfluidic and imaging technologies. Measurements were conducted at a temperature of 34 °C and at shear rates ranging from 3000 s<sup>-1</sup> to 30,000 s<sup>-1</sup> to mimic conditions during eye blinking. <b>Results</b>: Natural tears showed minimal change in viscosity in response to changes in shear stress, with viscosity values of 0.91 mPa·s at 3000 s<sup>-1</sup> and 0.80 mPa·s at 30,000 s<sup>-1</sup>. Among the artificial tear formulations, Thealoz<sup>®</sup> Duo had the lowest viscosity (2.62 ± 0.01 mPa·s at 3000 s<sup>-1</sup>), followed by Ivizia<sup>®</sup> (2.42 ± 0.02 mPa·s), Hylo Comod<sup>®</sup> (3.69 ± 0.01 mPa·s), Hylo Parin<sup>®</sup> (3.87 ± 0.01 mPa·s), Xailin HA<sup>®</sup> (4.73 ± 0.02 mPa·s), Vismed<sup>®</sup> (5.42 ± 0.02 mPa·s), and Systane Hydration<sup>®</sup> (7.76 ± 0.1 mPa·s). <b>Conclusions</b>: This study demonstrates that commercially available ocular lubricants exhibit varying degrees of shear-thinning behavior, a finding that is clinically relevant for their performance on the ocular surface. Formulations containing low-molecular-weight hyaluronic acid, such as Thealoz<sup>®</sup> Duo, exhibited viscosity values closest to those of natural tears at the measured shear rates.

Journal of Clinical MedicineVol. 14(24)
Nanyang Technological University (SG), Singapore National Eye Center (SG), Singapore Eye Research Institute (SG), Fondation Ophtalmologique Adolphe de Rothschild (FR), Duke-NUS Medical School (SG), He Eye Hospital (CN), Medical University of Vienna (AT)
Openalex Percentile: Top 37%
Gear and Bearing Dynamics Analysis
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.