Ammonia Chiller Performance Enhancement by Implementation of Ejector Overfeed Cycle with Brazed Plate Evaporator.

Ammonia has long been considered one the most promising refrigerants for refrigeration applications due to its favorable thermodynamic properties that yield high COP compared to most other common fluids. Evaporator overfeed in ammonia systems is often accomplished by means of a motor-driven pump; however, a simpler and more reliable method for overfeeding would be to use a liquid recirculation ejector. This paper presents the results of a study investigating the improvement that can be achieved in evaporator and cycle performance for a 20 kW nominal capacity ammonia chiller by overfeeding the evaporator. A two-phase ammonia ejector was designed based on previous in-house knowledge and experience with liquid recirculation ejectors; baseline system and ejector overfeed system capacity, COP, and evaporator performance are presented and compared, with simultaneous capacity and COP improvements of 28 and 22 %, respectively, observed with the overfeed system mainly due to the elimination of the superheated portion of the evaporator.

Authors

Institutions

Publication Details

Published
2026-10-15
DOI
https://doi.org/10.18462/iir.gl.2020.1013
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ammonia Chiller Performance Enhancement by Implementation of Ejector Overfeed Cycle with Brazed Plate Evaporator.

Pega Hrnjak, Stefan W. Elbel, Neal Lawrence, Joe Zheng
Refrigeration and Air Conditioning Technologies
article

Ammonia Chiller Performance Enhancement by Implementation of Ejector Overfeed Cycle with Brazed Plate Evaporator.

Pega Hrnjak, Stefan W. Elbel, Neal Lawrence, Joe Zheng
article en

Abstract

Ammonia has long been considered one the most promising refrigerants for refrigeration applications due to its favorable thermodynamic properties that yield high COP compared to most other common fluids. Evaporator overfeed in ammonia systems is often accomplished by means of a motor-driven pump; however, a simpler and more reliable method for overfeeding would be to use a liquid recirculation ejector. This paper presents the results of a study investigating the improvement that can be achieved in evaporator and cycle performance for a 20 kW nominal capacity ammonia chiller by overfeeding the evaporator. A two-phase ammonia ejector was designed based on previous in-house knowledge and experience with liquid recirculation ejectors; baseline system and ejector overfeed system capacity, COP, and evaporator performance are presented and compared, with simultaneous capacity and COP improvements of 28 and 22 %, respectively, observed with the overfeed system mainly due to the elimination of the superheated portion of the evaporator.

Creative Thermal Solutions (US)
Affordable and clean energy
Openalex Percentile: Top 100%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.