VALIDITY AND RELIABILITY OF MEASUREMENTS OF THE PARAMETERS OF SMILE AESTHETICS: A COMPARISON BETWEEN DIGITAL AND PLASTER MODELS

This study aims to evaluate the validity and reliability of the TRIOS3 Color intraoral scanner (3Shape A/S, Copenhagen, Denmark) and its associated Ortho Analyzer™ software in measuring parameters of smile aesthetics compared with measurements on plaster casts. The study sample comprised plaster casts and digital models obtained from 30 subjects. Height (H), mesiodistal diameter (MDD) and connecting space (CS) of the anterior teeth were measured with a digital calliper on the plaster models and with the orthodontic software on the digital models. Validity was assessed using a 2-tailed paired t-test; the reliability of measurements for intra-examiner was evaluated with the Intra-class Correlation Coefficient (ICC). There were no statistically significant differences between the measurements made with the two methods. The ICC is 99% for height and MDD measurements, slightly lower in the evaluation of the CS. Linear measurements made on digital model have clinically acceptable accuracy and reliability. The TRIOS3 Color intraoral scanner represents a valuable tool for dental practice, particularly in evaluating parameters of smile aesthetics.

Authors

Publication Details

Journal
EuroMediterranean Biomedical Journal
Published
2025-10-16
DOI
https://doi.org/10.3269/1970-5492.2020.15.18
Citations
1
Primary Topic
Olfactory and Sensory Function Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

VALIDITY AND RELIABILITY OF MEASUREMENTS OF THE PARAMETERS OF SMILE AESTHETICS: A COMPARISON BETWEEN DIGITAL AND PLASTER MODELS

Giuseppe Pizzo
1 citations
EuroMediterranean Biomedical Journal
Olfactory and Sensory Function Studies
article

VALIDITY AND RELIABILITY OF MEASUREMENTS OF THE PARAMETERS OF SMILE AESTHETICS: A COMPARISON BETWEEN DIGITAL AND PLASTER MODELS

Giuseppe Pizzo
article en
1 citations

Abstract

This study aims to evaluate the validity and reliability of the TRIOS3 Color intraoral scanner (3Shape A/S, Copenhagen, Denmark) and its associated Ortho Analyzer™ software in measuring parameters of smile aesthetics compared with measurements on plaster casts. The study sample comprised plaster casts and digital models obtained from 30 subjects. Height (H), mesiodistal diameter (MDD) and connecting space (CS) of the anterior teeth were measured with a digital calliper on the plaster models and with the orthodontic software on the digital models. Validity was assessed using a 2-tailed paired t-test; the reliability of measurements for intra-examiner was evaluated with the Intra-class Correlation Coefficient (ICC). There were no statistically significant differences between the measurements made with the two methods. The ICC is 99% for height and MDD measurements, slightly lower in the evaluation of the CS. Linear measurements made on digital model have clinically acceptable accuracy and reliability. The TRIOS3 Color intraoral scanner represents a valuable tool for dental practice, particularly in evaluating parameters of smile aesthetics.

EuroMediterranean Biomedical JournalVol. 15
Olfactory and Sensory Function Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.