A Study of the Short Wave-Length Limit of the Continuous X-Ray Spectrum

Because of the troublesome discrepancy among the natural atomic constants e, h and mo which has existed since 1935, a precision measurement of h/e by the short wave-length limit of the continuous x-ray spectrum is undertaken. The method used is the customary one of observing an isochromat, but several changes over previous practice are made in the apparatus and the experimental technique, and these are described in detail. Chief among these are: (a) an improved filament supply circuit and an electronic robot for stabilizing the voltage, (b) an elaborately calibrated precision resistance for measuring the voltage, (c) improved sensitivity in the ion chamber measurements of intensity, (d) the use of freshly cleaved crystals in the two-crystal monochromator to improve its resolving power and thereby reduce the fillet at the foot of the isochromat (made possible with the high intensity available from the Watters Memorial power supply and x-ray tube), (e) the use of Ross balanced filters to suppress the effect of non-coherently scattered radiation and to eliminate the integrated effect of the wings of the spectral transmission "window" of the monochromator, (f) an indirect cathode to preclude the existence of excess energy secondary electrons, and (g) a very clean target of high atomic number to insure a good intercept on the isochromat. The calibration of the voltmeter and of the spectrometer are not yet in a satisfactory state, but preliminary results give h/e= (1.38054 ± .00115) x 10-17 erg sec/esu. This is to be compared with the indirect value (obtained from combining the Rydberg constant, the x-ray value of e and the best value of e/mo ) of (1.37929 ± .00023) x 10-17 erg sec/esu. The overlapping of these probable errors demonstrates the resolution of the discrepancy. The experiment is quite capable of five times the stated precision after certain checks are made, and better results are expected soon.

Authors

Institutions

Publication Details

Journal
PhDT
Published
2025-02-04
DOI
https://doi.org/10.7907/dw87-7z48
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Study of the Short Wave-Length Limit of the Continuous X-Ray Spectrum

H. H. Bailey
2 links
PhDT
Digital Radiography and Breast Imaging
article

A Study of the Short Wave-Length Limit of the Continuous X-Ray Spectrum

H. H. Bailey
article en

Abstract

Because of the troublesome discrepancy among the natural atomic constants e, h and mo which has existed since 1935, a precision measurement of h/e by the short wave-length limit of the continuous x-ray spectrum is undertaken. The method used is the customary one of observing an isochromat, but several changes over previous practice are made in the apparatus and the experimental technique, and these are described in detail. Chief among these are: (a) an improved filament supply circuit and an electronic robot for stabilizing the voltage, (b) an elaborately calibrated precision resistance for measuring the voltage, (c) improved sensitivity in the ion chamber measurements of intensity, (d) the use of freshly cleaved crystals in the two-crystal monochromator to improve its resolving power and thereby reduce the fillet at the foot of the isochromat (made possible with the high intensity available from the Watters Memorial power supply and x-ray tube), (e) the use of Ross balanced filters to suppress the effect of non-coherently scattered radiation and to eliminate the integrated effect of the wings of the spectral transmission "window" of the monochromator, (f) an indirect cathode to preclude the existence of excess energy secondary electrons, and (g) a very clean target of high atomic number to insure a good intercept on the isochromat. The calibration of the voltmeter and of the spectrometer are not yet in a satisfactory state, but preliminary results give h/e= (1.38054 ± .00115) x 10-17 erg sec/esu. This is to be compared with the indirect value (obtained from combining the Rydberg constant, the x-ray value of e and the best value of e/mo ) of (1.37929 ± .00023) x 10-17 erg sec/esu. The overlapping of these probable errors demonstrates the resolution of the discrepancy. The experiment is quite capable of five times the stated precision after certain checks are made, and better results are expected soon.

PhDT
California Institute of Technology (US)
Openalex Percentile: Top 100%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.