Wind loads on double facade systems with gaps greater than 15 cm

The EUROCODE ENV 1991–2-4,Wind Loads consists of a method for calculating the resulting windloads on the two skins of external walls with more than one skin. For double facade systems, which are charcterized by a large distance between the two skins in a range of ≈0,4m up to 1,4m, the application of these method leads to a reduction of the resulting loads on the external skin, which underestimate the real loads significantly. For that reason model tests on three different buildings with double facades have been performed, and the dynamic loads on the external and internal skins were measured parallel. The results are presented in this paper and recommendations will be given for an improvement of the present code.

Authors

Publication Details

Published
2026-02-12
DOI
https://doi.org/10.1201/9781003761891-71
Citations
1
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wind loads on double facade systems with gaps greater than 15 cm

Michael Hortmanns, Frank Wellershoff
1 citations
Wind and Air Flow Studies
article

Wind loads on double facade systems with gaps greater than 15 cm

Michael Hortmanns, Frank Wellershoff
article en
1 citations

Abstract

The EUROCODE ENV 1991–2-4,Wind Loads consists of a method for calculating the resulting windloads on the two skins of external walls with more than one skin. For double facade systems, which are charcterized by a large distance between the two skins in a range of ≈0,4m up to 1,4m, the application of these method leads to a reduction of the resulting loads on the external skin, which underestimate the real loads significantly. For that reason model tests on three different buildings with double facades have been performed, and the dynamic loads on the external and internal skins were measured parallel. The results are presented in this paper and recommendations will be given for an improvement of the present code.

Affordable and clean energy
Openalex Percentile: Top 98%
Wind and Air Flow Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Wind loads on double facade systems with gaps greater than 15 cm — Michael Hortmanns, Frank Wellershoff · (2026) | TGRS Research Map | TGRS