Response control system with soft first story structure

The building plane is 7.75 m × 8.35 m and the height is 47.8 m. As the result, it became difficult to control the building response for not only seismic loading but also wind loading. So, we planed to change the vibration mode from the rocking-mode to the sway-mode by softening the translation stiffness at the first story, and to make the first story into the energy-absorbing story by concentrating the building deformation. We call this system the soft first story structure. The system consists of the following three items; (a) to stiffen the structure above the second story, (b) to make columns of the first story flexible laterally and rigid axially, (c) to develop the hardening-type oil-damper. In this paper, it is reported about details of these structural elements and the dynamic performance of the proposed response control system against wind and seismic loadings throughout the time history response analysis.

Authors

Institutions

Publication Details

Published
2026-02-04
DOI
https://doi.org/10.1201/9781003759638-110
Primary Topic
Advanced Malware Detection Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Response control system with soft first story structure

Yasuhiro Hayabe, Yuichi Watanabe
Advanced Malware Detection Techniques
article

Response control system with soft first story structure

Yasuhiro Hayabe, Yuichi Watanabe
article en

Abstract

The building plane is 7.75 m × 8.35 m and the height is 47.8 m. As the result, it became difficult to control the building response for not only seismic loading but also wind loading. So, we planed to change the vibration mode from the rocking-mode to the sway-mode by softening the translation stiffness at the first story, and to make the first story into the energy-absorbing story by concentrating the building deformation. We call this system the soft first story structure. The system consists of the following three items; (a) to stiffen the structure above the second story, (b) to make columns of the first story flexible laterally and rigid axially, (c) to develop the hardening-type oil-damper. In this paper, it is reported about details of these structural elements and the dynamic performance of the proposed response control system against wind and seismic loadings throughout the time history response analysis.

Taisei (Japan) (JP)
Climate action
Advanced Malware Detection Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.