NONLINEAR TIME-HISTORY ANALYSIS OF A BASE-ISOLATED RC BUILDING IN SHANGHAI FOUNDED ON SOFT SOIL

A 6-story RC building with base isolation using rubber bearings and viscous dampers has been recently built in Shanghai. \nSince the building is founded on soft soil, concern regarding base isolation suitability arose; even the Chinese design code does not recommend this solution for soft soil. To clarify this issue, nonlinear time-history analyses are carried out for a number of natural and artificial seismic inputs that represent the site seismicity, accounting for the soil conditions. The relevance of soil-structure interaction is discussed and some simulations are performed. Adequacy of base isolation is assessed both in the superstructure and the isolation layer. In the superstructure, appropriateness is judged in terms of reduction of interstory drift, absolute acceleration and shear force. In isolators, correctness is evaluated in terms of axial force, torsion angle and lateral displacement; prescriptions of Chinese and European regulations are considered. The major conclusion is that base isolation of ordinary mid-height RC buildings founded on soft soil can perform satisfactorily in medium seismicity regions.

Authors

Publication Details

Journal
RECERCAT (Consorci de Serveis Universitaris de Catalunya)
Published
2025-12-18
DOI
https://doi.org/10.71846/16-wcee-1230
Citations
1
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

NONLINEAR TIME-HISTORY ANALYSIS OF A BASE-ISOLATED RC BUILDING IN SHANGHAI FOUNDED ON SOFT SOIL

Bashar Alfarah, Dagen Weng, Tao Li
1 citations
RECERCAT (Consorci de Serveis Universitaris de Catalunya)
Seismic Performance and Analysis
article

NONLINEAR TIME-HISTORY ANALYSIS OF A BASE-ISOLATED RC BUILDING IN SHANGHAI FOUNDED ON SOFT SOIL

Bashar Alfarah, Dagen Weng, Tao Li
article en
1 citations

Abstract

A 6-story RC building with base isolation using rubber bearings and viscous dampers has been recently built in Shanghai. \nSince the building is founded on soft soil, concern regarding base isolation suitability arose; even the Chinese design code does not recommend this solution for soft soil. To clarify this issue, nonlinear time-history analyses are carried out for a number of natural and artificial seismic inputs that represent the site seismicity, accounting for the soil conditions. The relevance of soil-structure interaction is discussed and some simulations are performed. Adequacy of base isolation is assessed both in the superstructure and the isolation layer. In the superstructure, appropriateness is judged in terms of reduction of interstory drift, absolute acceleration and shear force. In isolators, correctness is evaluated in terms of axial force, torsion angle and lateral displacement; prescriptions of Chinese and European regulations are considered. The major conclusion is that base isolation of ordinary mid-height RC buildings founded on soft soil can perform satisfactorily in medium seismicity regions.

RECERCAT (Consorci de Serveis Universitaris de Catalunya)
Life in Land
Openalex Percentile: Top 100%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

NONLINEAR TIME-HISTORY ANALYSIS OF A BASE-ISOLATED RC BUILDING IN SHANGHAI FOUNDED ON SOFT SOIL — Bashar Alfarah, Dagen Weng, et al. · RECERCAT (Consorci de Serveis Universitaris de Catalunya) (2025) | TGRS Research Map | TGRS