Automatic accuracy evaluation for distance measurement by medical ultrasound scanners

Inrecent years several ultrasound (US) scanners for medical diagnosis was presented and specific methods for ultrasounds images quality evaluation was developed to verify the apparatuses performances. The proposed methods still depend on subjective evaluation, performed by expert operators, of images produced by dedicated test objects (US phantoms). Distance accuracy is usually evaluated on screen by means of device settings adjustment and use of electronic caliper implemented in the scanner, both set by the operator, and with methods not standardized; therefore results are dependent on adopted procedure. In present work, an automatic accuracy evaluation method for distance measurement by medical US scanners is developed. It adopts Point Spread Functions phantoms as reference and allows accuracy evaluations in vertical and horizontal distance measurements. Analysis is performed on uncompressed two-dimensional images produced by the scanner, with a least squares estimation on results. An index for global distance measurement accuracy is proposed.

Authors

Institutions

Publication Details

Published
2026-01-22
DOI
https://doi.org/10.1201/9781003759805-36
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automatic accuracy evaluation for distance measurement by medical ultrasound scanners

Annunziata D’Orazio, Andrea Scorza, Salvatore Andrea Sciuto, Francesco Branca
Flow Measurement and Analysis
article

Automatic accuracy evaluation for distance measurement by medical ultrasound scanners

Annunziata D’Orazio, Andrea Scorza, Salvatore Andrea Sciuto, Francesco Branca
article en

Abstract

Inrecent years several ultrasound (US) scanners for medical diagnosis was presented and specific methods for ultrasounds images quality evaluation was developed to verify the apparatuses performances. The proposed methods still depend on subjective evaluation, performed by expert operators, of images produced by dedicated test objects (US phantoms). Distance accuracy is usually evaluated on screen by means of device settings adjustment and use of electronic caliper implemented in the scanner, both set by the operator, and with methods not standardized; therefore results are dependent on adopted procedure. In present work, an automatic accuracy evaluation method for distance measurement by medical US scanners is developed. It adopts Point Spread Functions phantoms as reference and allows accuracy evaluations in vertical and horizontal distance measurements. Analysis is performed on uncompressed two-dimensional images produced by the scanner, with a least squares estimation on results. An index for global distance measurement accuracy is proposed.

Sapienza University of Rome (IT)
Openalex Percentile: Top 97%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Automatic accuracy evaluation for distance measurement by medical ultrasound scanners — Annunziata D’Orazio, Andrea Scorza, et al. · (2026) | TGRS Research Map | TGRS