A new multi-channel air ion spectrometer (AIS) is presented. The instrument allows simultaneous measurements of positive and negative ion distributions from 3.2 to 0.0013 cm 2 V -1 s -1 (0.80-40 nm diameter or, using the Tammet correction, from 0.4 to 40 nm). The mobility range is divided into 27 fractions which are measured simultaneously to ensure a high time resolution (down to 10 seconds). The instrument calibration shows a good agreement with the mobility of electrically-classified, mono-dispersed aerosols. The spectrometer overestimates low concentrations of cluster ions. This is caused by a natural production of small ions (< 1 nm, 10 to 100 cm -3 ) inside the spectrometer. The instrument specifications, calibration results and measurements performed show a huge application potential of the new spectrometer.

Authors

Publication Details

Journal
Työväentutkimus Vuosikirja
Published
2024-12-12
DOI
https://doi.org/10.60910/j57u-44r2
Citations
132
Primary Topic
Atmospheric chemistry and aerosols
Type
article
Field-Weighted Citation Impact
4.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A wide-range multi-channel air ion spectrometer

Markku Kulmala, Lauri Laakso, E. Tamm, Sander Mirme et al.
132 citations
Työväentutkimus Vuosikirja
Atmospheric chemistry and aerosols
4.52
article

A wide-range multi-channel air ion spectrometer

Markku Kulmala, Lauri Laakso, E. Tamm, Sander Mirme, A. Mirme, Anne Hirsikko, Marko Vana, Toomas Bernotas, Genrik Mordas, Janek Uin
article en
132 citations

Abstract

A new multi-channel air ion spectrometer (AIS) is presented. The instrument allows simultaneous measurements of positive and negative ion distributions from 3.2 to 0.0013 cm 2 V -1 s -1 (0.80-40 nm diameter or, using the Tammet correction, from 0.4 to 40 nm). The mobility range is divided into 27 fractions which are measured simultaneously to ensure a high time resolution (down to 10 seconds). The instrument calibration shows a good agreement with the mobility of electrically-classified, mono-dispersed aerosols. The spectrometer overestimates low concentrations of cluster ions. This is caused by a natural production of small ions (< 1 nm, 10 to 100 cm -3 ) inside the spectrometer. The instrument specifications, calibration results and measurements performed show a huge application potential of the new spectrometer.

Työväentutkimus VuosikirjaVol. 12(3)
Affordable and clean energy
Openalex Percentile: Top 5%
Atmospheric chemistry and aerosols
4.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.