Seismic performance of RC columns retrofitted with CFRP Strips

Reinforced concrete columns of the rail-way structures were severely damaged at 1995 Hyogoken-Nanbu earthquake. Observed main damage patterns in the reinforced concrete structures were shear failures of the columns with poor arrangements of the lateral reinforcement. For those columns, confinement of the column sections is effective to improve the ductility of the columns in avoiding the brittle failure. Authors proposed spacing the carbon fiber reinforced polymer (CFRP) strips for the retrofitting of those columns. This paper presents the seismic performance of reinforced concrete columns retrofitted with CFRP strips comparing with those of the columns with CFRP sheet. In this research program, seismic loading tests were performed using scaled reinforced concrete columns in the laboratory of the Hiroshima University. From test results, The columns retrofitted with CFRP strips showed the very good performance as same as CFRP sheet. Moreover, it is anticipated that there is strong possibility of decreasing the amount of CFRP.

Authors

Institutions

Publication Details

Published
2026-02-04
DOI
https://doi.org/10.1201/9781003759751-64
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic performance of RC columns retrofitted with CFRP Strips

Hideo Araki, Kenji Kabayama, R. Sato, Masamichi NAKATA
Structural Behavior of Reinforced Concrete
article

Seismic performance of RC columns retrofitted with CFRP Strips

Hideo Araki, Kenji Kabayama, R. Sato, Masamichi NAKATA
article en

Abstract

Reinforced concrete columns of the rail-way structures were severely damaged at 1995 Hyogoken-Nanbu earthquake. Observed main damage patterns in the reinforced concrete structures were shear failures of the columns with poor arrangements of the lateral reinforcement. For those columns, confinement of the column sections is effective to improve the ductility of the columns in avoiding the brittle failure. Authors proposed spacing the carbon fiber reinforced polymer (CFRP) strips for the retrofitting of those columns. This paper presents the seismic performance of reinforced concrete columns retrofitted with CFRP strips comparing with those of the columns with CFRP sheet. In this research program, seismic loading tests were performed using scaled reinforced concrete columns in the laboratory of the Hiroshima University. From test results, The columns retrofitted with CFRP strips showed the very good performance as same as CFRP sheet. Moreover, it is anticipated that there is strong possibility of decreasing the amount of CFRP.

Hiroshima University (JP)
Climate action
Openalex Percentile: Top 98%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Seismic performance of RC columns retrofitted with CFRP Strips — Hideo Araki, Kenji Kabayama, et al. · (2026) | TGRS Research Map | TGRS